Data Sheet 
Tech Updates
Oversize
Fitting Assembly Reduce Assembly Effort
Fluid Path Restriction
Tech
Data
BarbLock Assembly Removing
BarbLock
Testing
Pull
Off Testing Pressure Testing Irradiation
AutoClave Test Results
|
|
Reduce Assembly Effort
| |
When installing
BarbLock® Ultra-Secure Tubing Retainer onto a barbed fitting
with a seat or tube stop (figure
1), it is recommended that you hold the tubing back approximately 1mm (.040
in.) as shown in figure
2. The gap will allow the material displaced by the 360° compression a space
to move (figure
3). The lower the durometer of tubing the more important the gap (figure
5). The gap is also important when attaching high durometer tubing but the
amount of displacement is minimal (figure
4). For a quick and easy measurement use the BarbLock® assembly tool's
support shelf, it is 1mm in thickness (No other measuring is required). |
|