Pressure Testing
| 
|
|
|
|
|
Test No. TBT03020201 The assembly
was submerged under water and placed into a containment. Pressure was gradually
increased 50 PSI every five minutes to understand the point at which the sample
would permeate.
| |
|
|
Test No. TBT03020201 Air permeated
between the tube & fitting during the 450 to 500 PSI increment. Bubbles are
evident between the hose and the barbed fitting (Upper right). No catastrophic
failure in assembly at any point.
| |
|
|
Test No. TBT03020201 After the permeation at
462 PSI the sample continued to release air until that point at which the BarbLock
Retainer resealed the assembly at 285 PSI. This test confirmed BarbLock's Dynamic
Retention and Seal capabilities.
| |
|
|