Test: TBT08240101 Tubing: C-Flex® Tubing Barbed Fitting: Brass Multi Tier
Fitting Tubing: Burst Failure at 48 PSI BarbLock 375 Series: Passed
view larger image
Test: TBT08240102 Tubing: PharMed® Tubing Barbed Fitting: Brass Multi
Tier Fitting Tubing: Wall Burst Failure at 38 PSI BarbLock 500 Series:
Passed
view larger image
Test: TBT08240103 Tubing: Silicone Tubing Barbed Fitting: Brass Multi
Tier Fitting Tubing: Wall Failure at 42 PSI BarbLock 500 Series: Passed
view larger image
BarbLock®
Retainers pressure tested with various Pharmaceutical and Medical Tubing...
Pressure testing was conducted under water using standard 90 PSI shop air supply
with regulator. Testing started at 0 PSI, pressure was increased 5 PSI every 2
minutes until failure. Tubing failures as detailed above, no leaks were detected
with BarbLock® Retainers. | |